Mina sidor Kontakt
Din varukorg
DPD & FedEx – leveransdatum på produktsidan.
Behöver du hjälp? Fråga DistriNode AI.

UPS-system Digitus OnLine 10 kVA 10 kW

UPS-system Digitus OnLine 10 kVA 10 kW
UPS-system Digitus OnLine 10 kVA 10 kW
UPS-system Digitus OnLine 10 kVA 10 kW
UPS-system Digitus OnLine 10 kVA 10 kW
UPS-system Digitus OnLine 10 kVA 10 kW
UPS-system Digitus OnLine 10 kVA 10 kW
UPS-system Digitus OnLine 10 kVA 10 kW
UPS-system Digitus OnLine 10 kVA 10 kW
UPS-system Digitus OnLine 10 kVA 10 kW
UPS-system Digitus OnLine 10 kVA 10 kW
UPS-system Digitus OnLine 10 kVA 10 kW
UPS-system Digitus OnLine 10 kVA 10 kW
UPS-system Digitus OnLine 10 kVA 10 kW
UPS-system Digitus OnLine 10 kVA 10 kW
UPS-system Digitus OnLine 10 kVA 10 kW
UPS-system Digitus OnLine 10 kVA 10 kW
UPS-system Digitus OnLine 10 kVA 10 kW
UPS-system Digitus OnLine 10 kVA 10 kW
UPS-system Digitus OnLine 10 kVA 10 kW
UPS-system Digitus OnLine 10 kVA 10 kW
10 613,34 kr
PDF
PDF
Lager 1 Produktkod 325050 Modell DN-170107 Garanti 2 år

Leverans & returer

Beräknad leverans fredag 27 november
Du får löpande uppdateringar via vårt detaljerade spårningssystem
Betalningsalternativ
BetalkortVisaMastercardPayPalApple PayGoogle PayBanköverföring

Ställ en fråga – AI-assistenten svarar direkt.

Produktbeskrivning

The DIGITUS OnLine 10 kVA 10 kW UPS is a parallel-redundant, double-conversion rack/tower system designed to provide continuous, fail-safe power for industrial and network-critical applications. It delivers a high power factor (1.0) and high online efficiency to maximize usable output and reduce energy loss. The unit is compact (2U rack height) with a metal housing and supports external battery modules (ordered separately, part number DN-170108) to extend runtime. The UPS includes network management options and a user-friendly LCD for status monitoring and configuration. It has no internal batteries and supports parallel/redundant operation of up to four devices for increased availability.

Advantages

High power factor (1.0) and elevated active output allow more connected loads within the rated capacity, saving rack space and reducing system cost. The UPS operates with high efficiency in online double-conversion mode, improving energy management and lowering heat dissipation. A clear LCD display simplifies installation, configuration and daily operation. Compact rack/tower design requires only 2U of rack space. Multiple communication interfaces (RS232/USB, parallel port, SNMP slot) enable remote monitoring and control. Automatic battery self-test, fan speed control and REPO (Remote Emergency Power Off) increase component life and provide safe shutdown in emergencies. The system supports parallel or redundant configurations (up to four units) and external battery cabinets for scalable runtime.

Suitable for

  • Server rooms and data centers requiring high availability
  • Network edge and telecommunications equipment
  • Industrial control systems and automation
  • Critical infrastructure and monitoring systems

Key specifications

  • Model: DIGITUS OnLine 10 kVA 10 kW (MPN: DN-170107, EAN: 4016032473558)
  • Topology: Double-conversion (online) UPS
  • Rated output power: 10 kW
  • Power factor: 1.0
  • Form factor: Rack/tower, 2U height
  • Dimensions (W × D × H): 440 × 620 × 86.5 mm
  • Weight: 18 kg
  • Communication: RS232, USB Type-B, parallel port, SNMP slot
  • Batteries: External battery modules required (DN-170108); no internal batteries
  • Battery recharge time: 8 hours; charging current: 1 A

How to use

Install the UPS in a standard 19-inch rack using 2U of space or place it as a tower on a stable, ventilated surface. Connect the input mains and critical loads according to the site electrical design and local regulations. Fit external battery modules (DN-170108) if runtime extension is required; internal batteries are not supplied. Use the LCD display to view status, alarms and configuration menus. For remote monitoring and management, connect the USB Type-B or RS232 port and install compatible management software or insert an SNMP card in the dedicated slot. Configure parallel operation when deploying more than one unit, following the manufacturer’s parallel-connection procedure.

Recommendations

Place the UPS in a clean, temperature-controlled environment with adequate ventilation. Verify compatibility of external battery modules before installation. Schedule regular battery self-tests and monitor fan operation via the LCD or network management to ensure continuous availability.
Höjdpunkter
  • Server rooms and data centers requiring high availability
  • Network edge and telecommunications equipment
  • Industrial control systems and automation
  • Critical infrastructure and monitoring systems
  • Model: DIGITUS OnLine 10 kVA 10 kW (MPN: DN-170107, EAN: 4016032473558)
  • Topology: Double-conversion (online) UPS
  • Rated output power: 10 kW
  • Power factor: 1.0
  • Form factor: Rack/tower, 2U height
  • Dimensions (W × D × H): 440 × 620 × 86.5 mm
  • Weight: 18 kg
  • Communication: RS232, USB Type-B, parallel port, SNMP slot
  • Batteries: External battery modules required (DN-170108); no internal batteries
  • Battery recharge time: 8 hours; charging current: 1 A

Specifikationer

Specifikationer
Anslutning för nödavstängning (EPO)
Ja
Antal batterier som stöds
20
Antal ingångsfaser
1
Antal USB 2.0-portar
1
Antal utgångsfaser
1
Batteriets laddningstid
8 h
Bredd
440 mm
Crestfaktor
3:1
Displaytyp
LCD + LED
Djup
620 mm
Drifttemperatur (T-T)
0 - 40
ECO-läge
Ja
Effektfaktor
0.99
Formfaktor
Rackmonterad/tower
Förpackningens bredd
615 mm
Förpackningens djup
765 mm
Förpackningsvikt
20600 g
Harmoniserade systemet (HS)-kod
85078000
Höjd
86.5 mm
Höljesmaterial
Metall
Hot swap-batteri
Ja
Inbyggd fläkt
Ja
Ingångsfrekvens
45/66
International Protection (IP)-kod
IP20
Kallstart
Ja
Kylningstyp
Aktiv
Laddström
1 A
Ljudnivå
55 dB
Manual
Ja
Max. driftspänning in
276 V
Max. utgångsdriftspänning
240 V
Min. driftspänning in
120 V
Nätkontakt
Fast anslutning
Nödstopp (EPO)
Ja
Paketvolym
100682 cm³
Produktfärg
Svart
Rackkapacitet
2U
Storlek (tum)
19 "
Svarstid
20 ms
Total harmonisk distorsion (THD) för utspänning
5 %
Total övertonsdistorsion (THD) för ingångsström
5 %
Typ av USB-anslutning
USB Typ-B
UK-tullkod
85044086
UPS-topologi
Dubbelkonvertering (online)
Ursprungsland
Kina
USB-port
Ja
Utgångseffekt
10000 W
Utgångseffekt
6 kVA
Utgångsfrekvens
50/60
Utgångsfrekvensreglering
1
Utgångsspänning i drift (min.)
208 V
Utgångsspänningsreglering
5
Vågform
Ren sinusvåg
Verkningsgrad
93.5 %
Vikt
18 kg

Broschyr

Öppna Broschyr

Dokument

Öppna Dokument
Prishistorik för de senaste 6 månaderna
UPS-system Digitus OnLine 10 kVA 10 kW
Aktuell
10 613,34 kr
Lägsta 7 d
10 483,65 kr
Högsta 7 d
10 629,68 kr
Ändring 24 h
-15,28 kr   0%
Ändring 7 d
+129,69 kr   +1%
Ändring 30 d
+1 047,01 kr   +11%

Skriv en recension

Betyg *
Obs! HTML-kod tolkas inte!

Fler DIGITUS-produkter i den här kategorin

7

Populära produkter i den här kategorin

8
Säljare: UAB KUR LT · Gariūnų g. 57-14, LT-02300 Vilnius, Litauen · Org.nr 303192950 · Momsreg.nr LT100008198612 · Skickas från EU (Litauen)
WhatsApp
Messenger
Hej, jag är DistriNodes AI-assistent. Jag hjälper dig gärna att hitta produkter, jämföra alternativ, ta fram offerter som PDF eller skapa supportärenden.
Alla kategorier