Mina sidor Kontakt
Din varukorg
DPD & FedEx – leveransdatum på produktsidan.
Behöver du hjälp? Fråga DistriNode AI.

DSIT DANICOM CAT6 UTP 305 m solid ledare kabel – LSZH (B2ca) – DC-UTP6-305S-B2CA

DSIT DANICOM CAT6 UTP 305 m solid ledare kabel – LSZH (B2ca) – DC-UTP6-305S-B2CA
DSIT DANICOM CAT6 UTP 305 m solid ledare kabel – LSZH (B2ca) – DC-UTP6-305S-B2CA
2 772,33 kr
PDF
PDF
Lager 100 Produktkod 3372241 Modell DC-UTP6-305S-B2CA Garanti 2 år

Leverans & returer

Beräknad leverans fredag 11 december
Du får löpande uppdateringar via vårt detaljerade spårningssystem
Betalningsalternativ
BetalkortVisaMastercardPayPalApple PayGoogle PayBanköverföring

Ställ en fråga – AI-assistenten svarar direkt.

Produktbeskrivning

When network installers pull horizontal runs in office towers, schools, and hospitals, they need a cable that won’t turn a small fault into a smoke hazard. This DSIT DANICOM CAT6 UTP cable delivers a full 305-meter pull-box of solid bare copper, wrapped in a low-smoke zero-halogen jacket that meets the strict B2ca CPR classification. It handles Gigabit Ethernet and 250 MHz bandwidth without shielded complexity, making it a go-to for structured cabling where fire safety codes bite.

Key specifications

  • Category 6 performance, unshielded twisted pair (UTP) construction
  • Solid bare copper conductors, 23 AWG, 4 pairs
  • 305 m (1000 ft) pull-box for convenient installation
  • LSZH (Low Smoke Zero Halogen) outer jacket, CPR class B2ca
  • Supports 1000BASE-T Gigabit Ethernet up to 250 MHz
  • 100 Ohm impedance, compliant with ISO/IEC 11801, EN 50173, TIA/EIA-568-C.2
  • Indoor-rated for data networking in commercial and residential spaces

Why choose it

The B2ca fire rating and LSZH jacket make this cable a responsible choice for public buildings, schools, and hospitals where smoke emission and toxic fumes are critical concerns. Solid copper conductors ensure stable, long-distance signal integrity, while the pull-box packaging speeds up deployment on large projects. It is a cost-effective way to future-proof horizontal cabling without moving to shielded systems.

Ideal use cases

  • Structured cabling for office LANs and data centres
  • Horizontal runs from patch panels to workstations
  • Installations in risers, conduits, or cable trays

Good to know

This cable is supplied in a convenient pull-box, making it easy to dispense during installation. It is designed for indoor use only and should not be exposed to outdoor elements. The LSZH jacket reduces the amount of toxic and corrosive gases emitted during combustion, enhancing safety in occupied buildings.

Specifikationer

Specifikationer
EAN
8720289758950
Kabellängd
305 m
Kabelstandard
Cat6
Kategori
Nätverkskabel
Märke
DSIT
Modell
DANICOM CAT6 UTP 305m Solid Conductor Cable - LSZH (B2ca)
MPN
DC-UTP6-305S-B2CA
Rackkapacitet för utökade batterimoduler
305 m
Prishistorik för de senaste 6 månaderna
DSIT DANICOM CAT6 UTP 305 m solid ledare kabel – LSZH (B2ca) – DC-UTP6-305S-B2CA
Aktuell
2 772,33 kr
Lägsta 7 d
2 719,92 kr
Högsta 7 d
2 772,33 kr
Ändring 24 h
+37,88 kr   +1%
Ändring 7 d
+52,40 kr   +2%
Ändring 30 d
-509,32 kr   -16%

Skriv en recension

Betyg *
Obs! HTML-kod tolkas inte!

Samma serie och alternativ

5

Populära produkter i den här kategorin

8
Säljare: UAB KUR LT · Gariūnų g. 57-14, LT-02300 Vilnius, Litauen · Org.nr 303192950 · Momsreg.nr LT100008198612 · Skickas från EU (Litauen)
WhatsApp
Messenger
Hej, jag är DistriNodes AI-assistent. Jag hjälper dig gärna att hitta produkter, jämföra alternativ, ta fram offerter som PDF eller skapa supportärenden.
Alla kategorier